Server Technology PRO2 54-Outlets PDU

  • Part: 1768507
$3,800.10

Availability

Out of Stock

  • General Information
    • Manufacturer
    • Server Technology, Inc
    • Manufacturer Website Address
    • http://www.servertech.com
    • Brand Name
    • Server Technology
    • Product Series
    • PRO2
    • Product Type
    • PDU

The Server Technology® PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched "Primary" PDU can be connected to as many as three (with optional module) PRO2 Switched "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration

  • Warranty
    • Limited Warranty
    • 2 Year

  • Technical Information
    • PDU Type
    • Switched
    • Phase
    • Three Phase
    • Plug/Connector Type
    • IEC 60309 3P+G 9Hr 60A
    • Receptacle Type
    • IEC 60320 C13
    • Receptacle Detail
    • 54 x IEC 60320 C13
    • Protection Type
    • Branch Circuit
    • Circuit Protection
    • Circuit Breaker
    • Fuse
    • Features
    • LED Display
  • Power Description
    • Input Voltage
    • 230 V AC
    • Output Voltage
    • 208 V AC
    • Power Rating (Watt)
    • 17.30 kW
    • Input Current
    • 60 A
    • Input Frequency
    • 60 Hz
    • Circuit Breaker
    • Yes
  • Management
    • Management
      • HTTP/HTTPS
      • TLSv1.2
      • SSHv2
      • Telnet
      • SNMPv2c
      • v3 (GET, SET, Traps)
      • IPv4 and IPv6
      • LDAPv3/LDAPS
      • TACACS+
      • RADIUS
      • FTP/SFTP
    • Remote Outlet Switching
    • Yes
  • Interfaces/Ports
    • Network (RJ-45)
    • Yes
  • Physical Characteristics
    • Mount Type
    • Rack-mountable
    • Cabinet-mountable
    • Cord Length
    • 10 ft
    • Height
    • 80"
    • Width
    • 2.2"
    • Depth
    • 2.5"
  • Environmental Conditions
    • Minimum Operating Temperature
    • 32°F (0°C)
    • Maximum Operating Temperature
    • 140°F (60°C)
    • Minimum Operating Humidity
    • 8%
    • Maximum Operating Humidity
    • 90%
    • Minimum Storage Temperature
    • -40°F (-40°C)
    • Maximum Storage Temperature
    • 185°F (85°C)
  • Miscellaneous
    • Package Contents
      • PRO2 54-Outlets PDU
      • Button Mounts
    • Application/Usage
    • IT Equipment
    • Server Rack/Cabinet
    • Certifications & Standards
    • Safety (Listed & Certified, cTUVus mark):

      • UL 62368-1
      • CSA C22.2 No. 62368-1

      EMC:

      • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
      • CANICES-003, Class A